A well-designed commercial changeroom should give users enough storage, changing space and circulation without wasting valuable floor area.
Start with the number of people expected to use the facility at peak times, determine what they need to store, then select locker sizes and configurations that fit those requirements. From there, plan circulation, benches, wet areas, locker materials, locking systems, ventilation and installation requirements as one coordinated layout.
For workplaces, gyms, schools, sporting facilities and end-of-trip areas, the best locker room design is not simply the layout that fits the greatest number of lockers. It is the layout that provides enough usable storage while remaining comfortable, durable, easy to maintain and practical to operate.
1. Start With Peak Changeroom Demand
The first design question is:
How many people are likely to use the changeroom at the same time?
Do not base locker quantities only on:
• Total employees
• Total gym memberships
• Total student enrolment
• Daily visitors
Instead, estimate peak simultaneous use.
Consider:
• Shift changes
• Before-work and after-work peaks
• Class changeovers
• Sports sessions
• Gym class crossover
• Hybrid workplace attendance
• Contractors
• Visitors
• Seasonal demand
A workplace with 400 employees may only have 180 people on site during the busiest period.
A gym with several thousand members may only require storage for a fraction of that number at one time.
Where lockers are permanently assigned, the calculation changes because each eligible user may require their own compartment.
The existing FDB Lockers guide on how many lockers you need can help establish the required storage capacity before the physical changeroom layout is finalised.
2. Decide What Users Need to Store
Locker dimensions should be selected around actual belongings.
Typical changeroom storage may include:
• Backpacks
• Handbags
• Laptop bags
• Jackets
• Uniforms
• Shoes
• Towels
• Toiletries
• Sports bags
• Bicycle helmets
• Motorcycle helmets
• Work boots
• PPE
• Workwear
• Personal electronics
Office and End-of-Trip Users
Employees using end-of-trip facilities may carry considerably more than conventional office users.
They may require space for:
• Bicycle helmet
• Backpack
• Change of clothes
• Shoes
• Jacket
• Towel
• Toiletries
A small day-use locker that comfortably accommodates a handbag may be unsuitable for a cyclist.
Gym Users
Gym members may require room for:
• Sports bag
• Shoes
• Clothing
• Towel
• Toiletries
• Jacket
Industrial Employees
Industrial and trade workers may need larger compartments for:
• PPE
• Boots
• Uniforms
• Hard hats
• Jackets
• Equipment
The FDB Lockers guide to choosing the right locker size provides more detailed guidance on compartment dimensions and storage capacity.
3. Choose the Right Locker Door Configuration
Once storage requirements are known, decide how much vertical space each user needs.
Single-Door Lockers
Full-height lockers suit:
• Hanging uniforms
• Large bags
• Jackets
• Boots
• Helmets
• PPE
They provide maximum capacity but serve fewer people per locker bay.
Two-Door Lockers
Two-tier lockers can provide a useful balance between:
• Personal storage capacity
• User density
They are often suitable for:
• Gyms
• Schools
• General workplaces
• End-of-trip facilities
Three-Door Lockers
Three-tier configurations can suit users storing:
• Backpacks
• Shoes
• Folded clothing
• Personal belongings
They increase the number of users served without reducing compartment size as dramatically as higher-tier lockers.
Four-Door and Higher-Tier Lockers
Smaller compartments can suit:
• Phones
• Handbags
• Compact backpacks
• Temporary personal storage
• Visitor belongings
Higher door counts should not be selected solely because they increase the number of lockers.
If users cannot fit their normal belongings inside, the higher theoretical capacity provides little practical benefit.
4. Allow Enough Space in Front of the Lockers
Locker-room circulation is one of the most important layout considerations.
Users need room to:
• Stand in front of lockers
• Open doors
• Bend down
• Remove bags
• Change footwear
• Walk past other users
• Access benches
The room may feel adequately sized when empty but become congested when multiple locker doors are open.
Opposing Locker Banks
Where lockers sit on both sides of the room, consider:
locker depth + open-door zone + user zone + central circulation + opposing user zone
Do not simply measure the distance between closed locker fronts.
Busy Facilities
Schools, gyms and shift-based workplaces may experience many users arriving simultaneously.
Additional circulation can be more valuable than fitting another row of lockers into the room.
A commercial changeroom should remain functional during its busiest period, not only when one person is using it.
5. Position Benches Carefully
Bench seating can significantly improve changeroom usability.
It gives users somewhere to:
• Change shoes
• Sit while dressing
• Temporarily place a bag
• Organise belongings
However, benches also consume circulation space.
Central Benches
Central benches can work well in wider changerooms with locker banks around the perimeter.
Advantages include:
• Efficient use of open floor space
• Seating accessible from both sides
• Clear separation from locker fronts
Wall-Mounted or Integrated Benches
These can suit narrower areas but may reduce direct access to lower locker compartments.
Bench Placement
Check:
• Open locker-door clearance
• Walking space around benches
• Distance to opposing lockers
• Accessibility
• Cleaning access
• Emergency circulation
Avoid placing benches so close to locker banks that users cannot comfortably open doors while someone is seated.

6. Choose the Locker Material for the Environment
The locker material should match the level of moisture, impact and design importance within the changeroom.
Steel Lockers
Commercial steel lockers are commonly used in:
• Staff changerooms
• Schools
• Industrial facilities
• Warehouses
• Sporting facilities
• Dry gym areas
They offer practical rigidity and can provide strong value in larger installations.
Steel is generally most appropriate where:
• Conditions are reasonably dry
• Impact resistance matters
• Standard configurations are suitable
• An industrial or commercial aesthetic is acceptable
Laminate Lockers
Laminate lockers suit environments where appearance and integration with the interior are important.
Typical applications include:
• Corporate end-of-trip facilities
• Premium gyms
• Universities
• Office changerooms
• Architectural fitouts
Laminate can provide:
• Timber-look finishes
• Solid colours
• Flush doors
• Custom dimensions
• Integrated end panels
• Joinery-style appearance
Persistent water exposure still needs to be considered carefully.
Plastic Lockers
Commercial plastic lockers are particularly useful where moisture and corrosion resistance are priorities.
They can suit:
• Aquatic centres
• Pool changerooms
• Recreation centres
• Humid gym facilities
• Schools
• Wet-area environments
The right material should be selected according to the complete environment rather than appearance alone.
7. Separate Wet and Dry Zones Where Possible
A good commercial changeroom layout should consider how water moves through the room.
Typical wet areas include:
• Showers
• Pool access
• Basins
• Wet change areas
Dry areas may include:
• Locker banks
• Grooming areas
• Entry corridors
• Dry benches
Where practical, avoid positioning moisture-sensitive storage immediately beside persistent wet areas.
Benefits of Zoning
Separating wet and dry areas can help:
• Reduce water around lockers
• Protect finishes
• Improve cleaning
• Reduce slip risk
• Keep bags and clothing drier
• Improve user comfort
Floor Falls and Drainage
Wet changerooms may include floors sloping toward drains.
Locker locations should account for these falls.
A long bank installed across a significant floor gradient may require:
• Adjustable feet
• Raised bases
• Custom plinths
• Alternative positioning
The installation should be planned around the finished floor condition.
8. Plan Ventilation and Airflow
Changerooms can accumulate:
• Humidity
• Damp clothing
• Odours
• Heat
Building ventilation should therefore be considered alongside locker design.
Locker ventilation may also be useful where users store:
• Sports clothing
• Workwear
• Shoes
• Towels
• PPE
Steel Locker Ventilation
Steel locker doors may include vents or perforations depending on the selected range.
Plastic Locker Ventilation
Plastic locker construction varies, so check available ventilation features for the specific model.
Laminate Locker Ventilation
Custom laminate systems may incorporate ventilation through:
• Door perforations
• Gaps
• Grilles
• Carcass design
Locker ventilation should complement rather than replace appropriate room ventilation.
9. Choose a Locking System That Matches the Facility
Commercial changeroom lockers can use:
• Key locks
• Padlatches
• Mechanical combination locks
• Electronic keypad locks
• RFID locks
• NFC locks
• Hardwired access systems
FDB Lockers offers a range of locker locks suited to different allocation models.
Permanent Staff Lockers
Assigned staff lockers may work well with:
• Keys
• Private-mode combination locks
• Electronic locks
• RFID credentials
Shared Workplace Lockers
Flexible workplaces may benefit from:
• Public-mode digital locks
• RFID credentials
• Centrally managed access systems
Gym Lockers
Day-use gym lockers often benefit from systems that do not require long-term physical-key allocation.
Options can include:
• Combination locks
• RFID access
• Electronic locks
The best lock is the one that creates the least friction for both the user and the person administering the locker system.
10. Plan End-of-Trip Lockers Around Commuter Needs
End-of-trip facilities have become an important part of many commercial workplaces.
Users may arrive by:
• Bicycle
• Running
• Walking
• Motorcycle
• Public transport
Their storage needs can differ significantly from standard office lockers.
A commuter may need to store:
• Helmet
• Backpack
• Shoes
• Work clothes
• Cycling clothing
• Towel
• Toiletries
Consider Larger Compartments
Full-height or larger two-tier lockers may provide greater flexibility for active commuters.
Include Shoe and Helmet Space
Do not assume that a narrow locker compartment will accommodate a bicycle helmet.
Allow for Wet Items
Users may return during rain or place damp towels and clothing inside lockers.
Material choice and ventilation become particularly important in these facilities.
The FDB Lockers office locker range includes options that can be incorporated into workplace and end-of-trip storage areas.
11. Consider Cleaning and Maintenance
Changerooms require frequent cleaning.
Design decisions should allow cleaning staff to reach:
• Floors
• Locker bases
• Corners
• Bench surrounds
• Wall junctions
Locker Stands
Raised locker stands can make cleaning beneath units easier.
Plinths
Enclosed plinths create a more integrated appearance but should be specified appropriately where floors are regularly wet.
Sloping Tops
Sloping locker tops can:
• Discourage users from storing items above lockers
• Reduce dust collection
• Simplify cleaning
Materials
Cleaning products must suit the locker surface.
Avoid assuming that one cleaning chemical is appropriate for:
• Powder-coated steel
• Laminate
• ABS plastic
• HDPE plastic
• Electronic lock components
12. Coordinate Privacy With Locker Placement
Commercial changerooms need to balance visibility and privacy.
Locker banks can sometimes help create informal zones within larger rooms, but they should not:
• Block circulation
• Create hidden unsafe corners
• Restrict supervision unnecessarily
• Interfere with ventilation
• Obstruct emergency routes
In facilities with showers or changing cubicles, sightlines from:
• Entrances
• Corridors
• Public areas
should be considered carefully.
The final arrangement may require input from the project architect or building professional where privacy, accessibility or code requirements apply.
13. Plan Accessibility From the Beginning
Accessibility should not be added as an afterthought.
Consider:
• Clear circulation
• Locker reach heights
• Lock operating height
• Bench positioning
• Door operation
• Accessible routes
• Floor clearances
Not every compartment within a multi-tier locker bank is equally usable.
Very high lockers may be difficult for some users to reach, while very low compartments may require excessive bending.
Where the project is subject to specific accessibility requirements, these should be confirmed with the relevant building professional during design.
14. Coordinate Electrical Services Before Installation
Some commercial changerooms require electrical infrastructure for:
• Electronic locks
• RFID systems
• Hardwired access control
• Device charging
• Grooming appliances
• Lighting
Plan electrical requirements before lockers are installed.
Electronic Locker Systems
Depending on the system, requirements may include:
• Power supplies
• Controllers
• Data cabling
• Wireless gateways
• Programming hardware
Powered Lockers
If lockers include device charging, coordinate:
• Outlet locations
• Cable management
• Circuit capacity
• Ventilation
• Service access
Electrical work is considerably easier before the locker bank is installed.
15. Coordinate the Changeroom With the Rest of the Fitout
Lockers interact with many other elements.
Coordinate them with:
• Flooring
• Wall finishes
• Plumbing
• Electrical services
• Mirrors
• Basins
• Showers
• Hand dryers
• Joinery
• Benches
• Doors
• Fire services
• Mechanical ventilation
Late changes to one trade can affect the locker installation.
For example:
• A basin may reduce available wall length
• A new electrical cabinet may occupy a planned locker bay
• A deeper bench may restrict circulation
• Changed skirting may prevent lockers sitting against the wall
The FDB Lockers article on preparing for locker installation covers these site-coordination requirements in greater detail.
16. Avoid Common Commercial Changeroom Design Mistakes
Maximising Locker Quantity at the Expense of Circulation
More lockers are not useful when users cannot comfortably access them.
Selecting Compartments Before Checking Belongings
Locker dimensions should follow storage requirements.
Using the Same Locker Size for Every User
Office staff, cyclists and industrial workers may need very different storage capacity.
Ignoring Wet-Area Conditions
Locker material and base construction should suit expected moisture exposure.
Adding Benches After the Locker Layout Is Finished
Bench seating should be incorporated into the circulation plan from the beginning.
Selecting Locks Too Late
Lock preparation, power and access-control integration can affect the locker design.
Ignoring Floor Falls
Large banks across sloping wet-area floors may be difficult to level.
Forgetting Cleaning Access
Areas beneath, beside and above lockers need to be maintained.
Designing Only for Current User Numbers
Allow for realistic workforce, membership or student growth.
Treating Every Changeroom the Same
A corporate end-of-trip facility has different requirements from a school, gym, aquatic centre or industrial workplace.
Commercial Changeroom Design Checklist
Before approving the layout, confirm:
• Peak number of users
• Assigned or shared lockers
• Items being stored
• Required locker dimensions
• Door configuration
• Number of compartments
• Locker material
• Moisture exposure
• Ventilation requirements
• Locker locking system
• Bench requirements
• Circulation space
• Door-opening clearance
• Wet and dry zones
• Floor falls
• Cleaning access
• Accessible storage
• Electrical services
• End panels and fillers
• Plinth or stand design
• Sloping tops
• Delivery access
• Installation sequence
• Future growth allowance

Conclusion
Effective commercial changeroom design begins with users rather than locker quantities.
Determine how many people will use the facility at peak times, identify what they need to store and select locker sizes that provide appropriate capacity. The locker layout should then be coordinated with benches, circulation, wet areas, ventilation, locks, electrical services and cleaning requirements.
Steel lockers can provide robust, economical storage in many dry commercial environments. Laminate lockers can create a more architectural appearance in premium workplaces and end-of-trip facilities. Plastic lockers can provide valuable corrosion resistance in humid and wet changerooms.
FDB Lockers can assist with locker selection, layout planning, custom configurations, locking systems, delivery and installation for workplace, gym, school and commercial changeroom projects.
For assistance planning a new facility, contact FDB Lockers.













