The correct locker quantity is based on peak demand, not simply the total number of employees, students, members or visitors attached to a facility.
Assigned lockers usually require one compartment for each named user, plus an allowance for growth, replacements and operational flexibility. Shared lockers should be calculated from the highest number of people likely to need storage at the same time, adjusted for expected locker uptake and the facility’s access policy.
Locker size and door configuration must then be considered. A bank of four-door lockers may provide more compartments than single-door lockers within the same wall length, but smaller compartments may not accommodate school bags, uniforms, helmets or gym equipment.
1. Start With the Locker Allocation Model
The first decision is whether lockers will be assigned, shared or used for short periods.
Assigned Lockers
An assigned locker remains allocated to one person for a defined period.
This model is common for:
• School students
• Permanent employees
• Industrial staff
• Emergency-service personnel
• Employees storing uniforms or protective equipment
• Members with paid permanent locker access
Assigned storage is straightforward to calculate because each eligible user generally needs one compartment.
Use:
Required compartments = assigned users + spare and growth allowance
For example, a school planning storage for 480 students may decide to provide one locker per student and a 5% operational reserve.
480 × 1.05 = 504 compartments
The allowance should reflect the school’s projected enrolment, expected damaged compartments, timetable arrangements and future building use rather than an arbitrary percentage.
Shared Lockers
Shared lockers are used by different people at different times.
This model can suit:
• Hot-desking workplaces
• Gyms and aquatic centres
• Visitors
• Casual staff
• Contractors
• University facilities
• Short-stay recreation venues
Shared storage should be based on peak concurrent demand rather than the total number of daily users.
Short-Stay or Transactional Lockers
Some lockers are used for only a few hours before becoming available again.
Examples include:
• Gym visits
• Pool sessions
• Workplace day lockers
• Visitor storage
• Event facilities
• Temporary contractor storage
The quantity depends on session overlap, visit duration, peak attendance and how effectively lockers are released after use.
2. Count Users at the Busiest Time
Daily, weekly or annual visitor totals do not reveal how many lockers are required at one moment.
Identify the maximum realistic number of users present during the busiest operating period.
Schools
Consider:
• Current enrolment
• Projected enrolment
• Staff requiring storage
• Separate sports or music storage
• Students sharing campuses
• Year groups using different locker areas
• Part-time or visiting students
• Future classroom expansion
Schools using assigned lockers will normally begin with eligible student and staff numbers.
The quantity may be divided by year level, building, learning area or timetable zone rather than treated as one central pool. FDB Lockers provides dedicated school lockers in different materials and configurations for education facilities.
Workplaces
Use the maximum expected on-site workforce rather than total payroll headcount.
Account for:
• Hybrid attendance patterns
• Shift overlap
• Contractors
• Visitors
• Casual employees
• End-of-trip users
• Uniform storage
• Device storage
• Future recruitment
A business with 300 employees may not need 300 personal lockers when only 170 people are expected on site at peak attendance and not every role requires permanent storage.
The calculation changes when lockers are assigned rather than shared. FDB Lockers offers office lockers for personal storage, device storage and modern workplace applications.
Gyms and Recreation Facilities
Do not calculate gym locker quantities from membership numbers.
Use:
• Peak simultaneous attendance
• Average session duration
• Class crossover
• Pool and gym overlap
• Changeroom split
• Locker uptake
• Member and staff storage
• Day-use policy
A facility may have thousands of members but only a fraction attending during the busiest period.
Review gym lockers according to expected traffic, humidity, compartment size and the chosen lock-management model.
3. Calculate Assigned Locker Quantities
Assigned locker projects are normally the simplest to calculate.
Use:
Assigned lockers required = eligible assigned users × allocation rate
Then add the chosen allowance:
Final quantity = assigned lockers required × (1 + allowance)
The allocation rate may be 100% when every eligible user receives a locker. It may be lower when only selected departments, year levels or roles receive permanent storage.
Separate Different User Groups
Calculate each user group independently.
For example:
• 420 student lockers
• 35 teaching-staff lockers
• 18 administration lockers
• 12 sports-staff lockers
• 10 spare compartments
This produces a more useful plan than specifying 495 identical lockers.
Different groups may require different:
• Compartment sizes
• Materials
• Door configurations
• Colours
• Locations
• Locks
• Internal fittings
A staff member storing a laptop and handbag does not necessarily need the same locker as a student storing books, a school bag and sports equipment.
Avoid Inflating the Reserve Without a Reason
Extra lockers provide flexibility but consume wall space and budget.
The reserve should be based on:
• Forecast growth
• Expected damage or maintenance
• New-starter requirements
• Seasonal staff
• Enrolment changes
• Reallocation needs
• Project lifespan
Document the allowance used so future stakeholders understand why the quantity exceeds the current user count.
4. Calculate Shared and Day-Use Locker Quantities
Shared-locker calculations require more operational information.
Use:
Shared compartments required = peak concurrent users × expected locker uptake
Then add a reserve:
Final quantity = shared compartments × (1 + operational allowance)
Suppose a recreation facility expects 90 users in the changerooms during its busiest crossover period. If approximately 70% are expected to use lockers and the project includes a 10% reserve:
90 × 0.70 × 1.10 = 69.3
Round up to 70 compartments.
This is only an example. The correct inputs should come from attendance data, observation, access records, bookings or facility-management estimates.
Consider Turnover Carefully
High daily turnover does not automatically reduce the quantity needed.
One locker can serve several people per day only when:
• Users vacate it reliably
• Visit periods do not overlap excessively
• The lock returns to public mode correctly
• Forgotten items are managed promptly
• Cleaning does not remove too many lockers from use
• Users do not claim lockers for extended periods
A facility operating continuous peak demand may need almost one locker per concurrent user even if each locker changes hands several times.
Shared Workplace Lockers
For a flexible workplace, consider:
• Peak desk occupancy
• Percentage of employees bringing bags
• Employees requiring permanent storage
• Hybrid attendance patterns
• Visitor lockers
• End-of-trip lockers
• Lockers temporarily unavailable
• Separate device lockers
Do not combine permanent personal storage and day lockers into one undifferentiated quantity.
5. Match Compartment Size to Stored Items
Locker numbers cannot be finalised until the compartment size is confirmed.
A design may fit 300 small compartments into a room but still fail if users need to store large bags, uniforms or equipment.
List the largest normal items.
School Storage
Students may need space for:
• School bags
• Books and folders
• Jackets
• Lunch boxes
• Sports equipment
• Musical instruments
• Helmets
• Laptops or tablets
Primary-school, secondary-school and specialist-facility requirements can differ substantially.
Workplace Storage
Employees may store:
• Laptop bags
• Handbags
• Backpacks
• Helmets
• Cycling clothing
• Shoes
• Uniforms
• Personal protective equipment
• Coats
A compact day locker may suit a phone and small bag but not an employee arriving by bicycle with a helmet and change of clothing.
Gym and Changeroom Storage
Users may bring:
• Sports bags
• Shoes
• Towels
• Toiletries
• Helmets
• Coats
• Wet clothing
• Training equipment
Large full-height compartments provide greater capacity, while multi-tier lockers improve user density.
The most efficient design is not the one with the highest number of doors. It is the configuration that accommodates the expected items without wasting space.
6. Convert Compartment Demand Into Locker Units
Lockers are purchased as cabinets, bays or banks containing one or more compartments.
Use:
Locker units required = total compartments ÷ compartments per unit
Always round up to a complete unit.
For example, a facility requiring 154 compartments and using four-door units would need:
154 ÷ 4 = 38.5
The project therefore requires at least 39 four-door units, providing 156 compartments.
Common Configurations
Depending on the range, configurations may include:
• Single-door lockers
• Two-door lockers
• Three-door lockers
• Four-door lockers
• Six-door lockers
• Eight-door lockers
• Twelve-door lockers
• Step lockers
• Z-door lockers
• Device and phone lockers
A single-door unit offers maximum compartment height but serves fewer users per bay.
A multi-door unit serves more people within the same approximate footprint but reduces individual storage capacity.
The standard steel locker range includes several door configurations that can be assessed against the project’s storage and density requirements.
7. Separate Different Storage Purposes
One locker calculation should not automatically cover every requirement within the facility.
Create separate quantities for:
• Permanent personal lockers
• Day-use lockers
• Visitor lockers
• Staff lockers
• Student lockers
• Device lockers
• Uniform lockers
• Equipment lockers
• Accessible locations
• Spare compartments
Device Storage
Phone, tablet and laptop lockers use smaller compartments than personal-storage lockers.
They may therefore be installed as a separate high-density bank.
Consider:
• Device dimensions
• Charging requirements
• Power access
• Ventilation
• Cable management
• Supervision
• User allocation
Uniform and Equipment Storage
Uniforms, helmets and protective equipment may require:
• Full-height compartments
• Hanging rails
• Coat hooks
• Shelves
• Ventilation
• Greater depth
• Boot storage
Trying to incorporate these users into a small multi-tier locker count can create an apparent surplus of compartments that do not meet the actual storage need.
8. Allow for Growth, Maintenance and Operational Downtime
A locker bank rarely remains fully available for its entire service life.
Temporary reductions in capacity may result from:
• Damaged doors
• Lock faults
• Cleaning
• Lost credentials
• Items left behind
• Reconfiguration
• New starters
• Increased enrolment
• Workforce growth
• Temporary projects
Select an allowance that reflects the facility’s circumstances.
Growth
Consider the likely user population over the intended planning period.
A school with confirmed additional classrooms may require a larger reserve than a facility with stable enrolment.
A workplace moving toward greater on-site attendance may need more capacity than current hybrid-use data suggests.
Maintenance
Large installations benefit from having a small number of unassigned compartments available while faults are addressed.
The reserve should not replace proper maintenance planning. Locks, doors and accessories still need to remain serviceable.
Future Reconfiguration
Modular locker ranges can make later expansion easier, but exact colours, dimensions and components may change over time.
Where future expansion is likely:
• Reserve suitable wall space
• Record product specifications
• Retain finish information
• Plan power and data requirements
• Avoid blocking expansion areas with fixed services
9. Test the Quantity Against the Room Layout
The calculated quantity must fit the room safely and practically.
Measure:
• Available wall length
• Ceiling height
• Room depth
• Door swings
• Windows
• Columns
• Services
• Benches
• Circulation paths
• Accessible routes
• Cleaning access
• Installation access
Calculate Locker-Bank Width
Use:
Total bank width = number of bays × bay width
Then include:
• End panels
• Fillers
• Gaps
• Wall irregularities
• Corners
• Joinery panels
• Service clearance
Do not assume the exact room width can be filled with locker carcasses.
Walls may be out of square, skirtings may project and existing services may require clear space.
Check Door Operation
Locker doors should open without:
• Striking benches
• Blocking entry doors
• Colliding with opposing locker banks
• Obstructing circulation
• Hitting nearby joinery
• Restricting access to other compartments
A high compartment count provides little value when users cannot stand comfortably in front of the lockers.

10. Finalise Locks, Numbering and Project Requirements
The chosen access method affects how lockers are allocated and managed.
Options can include:
• Key locks
• Padlatches
• Mechanical combination locks
• Digital keypad locks
• RFID or NFC locks
• Hardwired access-control systems
The locker lock range supports different assigned and shared-use models across steel, laminate, plastic and device lockers.
Assigned Use
Assigned lockers commonly use:
• Key locks
• Private-mode digital locks
• Mechanical combinations
• RFID credentials linked to users
Shared Use
Day-use lockers may use:
• User-selected combinations
• Public-mode digital locks
• RFID cards or wristbands
• Centrally managed access systems
The locking method should support the allocation model. A large shared facility may become difficult to administer when every user requires a physical key.
Numbering
Plan numbering before installation.
Locker numbers may need to align with:
• Student records
• Employee records
• Membership software
• Building zones
• Floor plans
• Year groups
• Departments
• Cleaning schedules
Use a consistent numbering structure that can accommodate future expansion.
Delivery and Installation
Check:
• Loading access
• Doorway dimensions
• Lift sizes
• Corridor turns
• Stair access
• Floor protection
• Assembly requirements
• Wall fixing
• Sequencing with other trades
FDB Lockers supplies standard and custom locker options and provides project consultation, delivery and installation services for commercial locker projects.
Common Locker-Quantity Mistakes
Using Total Population Instead of Peak Demand
Daily visitors, total employees or complete membership numbers may significantly overstate the quantity required for shared lockers.
Ignoring Different User Groups
Students, staff, visitors and contractors may require different sizes and access methods.
Maximising Door Count Without Checking Capacity
More compartments do not help when bags and equipment do not fit.
Forgetting Spare Capacity
A fully allocated installation leaves no flexibility for faults, growth or temporary users.
Applying an Arbitrary Percentage
Growth and operational allowances should be based on actual project conditions.
Ignoring Room Circulation
A calculated locker bank may technically fit while leaving insufficient space for users, benches and open doors.
Choosing Locks After the Locker Order
Lock preparation, programming, wiring and administration should be considered during specification.
Failing to Round Up Complete Units
Locker quantities must be converted into complete cabinets or bays.
Final Locker Quantity Checklist
Before approving the order, confirm:
• Assigned, shared or short-stay use
• Peak concurrent users
• Eligible assigned users
• Locker uptake assumptions
• Growth allowance
• Maintenance reserve
• Separate staff and visitor requirements
• Device-storage requirements
• Largest stored item
• Required compartment dimensions
• Door configuration
• Compartments per unit
• Total cabinet quantity
• Locker-bank width
• Bench and circulation space
• Door-opening clearance
• Locking method
• Numbering structure
• Delivery route
• Installation requirements
• Future expansion space

Conclusion
The correct number of lockers is determined by how many people need storage at the busiest time, how the lockers are allocated and what users need to store.
Assigned facilities generally begin with one compartment per eligible user plus an appropriate reserve. Shared facilities should calculate peak concurrent demand, expected locker uptake and operational capacity. The result must then be converted into complete locker units and tested against the available room layout.
Compartment size, door configuration, locking, circulation and future growth are as important as the initial user count. FDB Lockers can assist with standard and custom locker planning for schools, workplaces, gyms and other commercial facilities.