Single, double and triple school-locker banks can use the same compartment format while changing the width and number of doors supplied as one unit. The best choice depends on available wall runs, delivery access, installation staging and how the locker count will be distributed across the school.
Do not select a bank size from price or door count alone. Map every proposed location, then compare how different module widths fit around corners, doors, services and circulation routes.
Understand What Single, Double and Triple Mean
For the heavy-duty school-locker products discussed here, “single”, “double” and “triple” describe the number of locker columns in the supplied unit—not three different compartment heights.
The live Steelco Heavy Duty School Lockers – Single listing is 380mm wide, 580mm deep and 1830mm high. It is the narrowest module in this comparison.
The double school-locker unit is listed at 760mm wide with six doors, while the triple school-locker unit is 1140mm wide with nine doors. Both share the listed 580mm depth and 1830mm height.
These live dimensions provide a planning reference, but confirm the current product and final configuration before ordering. Installation tolerances, surrounding building elements and any end panels or other project components still need to be allowed for.
Use Single Modules for Irregular Runs
A single-width module can help use a short section of wall, complete the end of a bank or fit between fixed constraints. It can also make quantities easier to distribute across several smaller locations.
That flexibility does not mean every narrow gap is suitable. Check door swing, user space, skirtings, wall projections and the installer’s ability to position and secure the unit.
Single modules may create more joins across a long locker run. Ask how units will be aligned and banked, and whether any additional components or labour apply to the proposed arrangement.
Use Double Modules for Repeating Classroom or Corridor Zones
A double unit can provide a practical repeating module where wall runs are regular and locker quantities need to be divided across year levels, classrooms or building zones.
Its 760mm listed width may be easier to coordinate than a triple bank where access turns, lift dimensions or installation staging are tight. The correct conclusion depends on the complete delivery route, not only the corridor wall.
When comparing several double units with a mixture of single and triple units, count doors and modules separately. A schedule that lists only “lockers” can become ambiguous during ordering and installation.
Use Triple Modules Where Long Runs and Access Allow
A triple unit provides nine doors in a listed 1140mm-wide bank. It may reduce the number of separate modules required along a long, uninterrupted wall.
Before selecting it, confirm the packaged or assembled delivery dimensions, weight and handling method. A product that fits the final wall may not pass through a lift, doorway or tight turn using the intended delivery method.
Also check how the wider unit will be staged during installation. Confirm who is responsible for unloading, positioning, banking and securing the lockers, and whether rooms or corridors need to be isolated.
Match the Compartment to What Students Store

The bank width determines how many columns arrive together; it does not answer whether the compartment itself suits the students’ belongings.
List what users need to store, such as bags, books, lunch boxes, sports equipment or devices. Use representative items to test the compartment rather than relying only on external cabinet dimensions.
The three linked products are currently listed with double-skinned steel doors, ventilation holes, nameplate inserts and padlatch hasps as standard. Confirm whether that configuration suits the school’s identification, airflow and lock-management requirements.
If long sporting equipment or bulky bags must be stored, these particular compartment proportions may not suit every user. Keep specialist storage requirements as a separate line in the schedule rather than forcing one locker type across the entire campus.
Build a Location-by-Location Locker Schedule
Create one row for every proposed locker bank and record:
- Building, level and exact location.
- Available wall width and relevant site constraints.
- Required door quantity.
- Proposed single, double and triple modules.
- User group and typical stored items.
- Locking and numbering requirements.
- Delivery route and installation timing.
- Responsibility for positioning, banking and securing.
Use the schedule to test the total quantity. For example, one triple unit and one double unit provide 15 doors across two modules; five single units may provide the same door count but create a different delivery and installation task.
Do not assume the mathematically shortest combination is the best. A mixture of modules can make better use of several wall runs and simplify staged work.
Check Doors, Corners and Circulation

Mark the locker depth and door-opening area on the floor. Add the space occupied by students standing in front of open lockers, then test the main circulation route during busy periods.
Keep banks clear of doorways, fire equipment, controls and other items that must remain accessible. Have the proposed layout reviewed against the school’s building, access and safety requirements.
At corners, confirm that adjacent locker doors can open without colliding. At the end of a run, check whether wall returns, skirtings or columns will affect positioning.
Confirm Delivery and Installation Before Finalising Modules
Inspect the complete route from the delivery point to every locker location. Measure doors, corridors, turns and lifts, and record floor-level or time restrictions.
The three linked products are currently described as delivered assembled. That makes delivery access particularly important. Confirm the current delivery arrangement and exact handling requirements for the order rather than assuming every site or quantity is managed identically.
Ask the quotation to separate lockers, freight, positioning, installation and any site-specific work. The final layout should identify each module by location so the delivery team knows where every unit belongs.
To have the module mix and access route reviewed together, request a school-locker quote from FDB Lockers. Attach the location schedule, photographs and measured delivery route.